{"id":2,"date":"2020-12-10T14:18:37","date_gmt":"2020-12-10T14:18:37","guid":{"rendered":"http:\/\/rolexiron.com\/?page_id=2"},"modified":"2020-12-24T14:09:04","modified_gmt":"2020-12-24T14:09:04","slug":"sample-page","status":"publish","type":"page","link":"https:\/\/rolexiron.com\/index.php\/sample-page\/","title":{"rendered":"Signaling Relays"},"content":{"rendered":"\n<figure class=\"wp-block-table\"><table><tbody><tr><td><strong>Product Code<\/strong><\/td><td><strong>Description<\/strong><\/td><td><strong>Approved By<\/strong><\/td><\/tr><tr><td>Relay AC LED.<\/td><td>Relay, plug-in-type,&nbsp;<strong>Style* \u2018AC LED\u2019&nbsp;<\/strong>all aspects, AC Lamp proving relay unit with in-built current transformer type, slow release neutral line relay,&nbsp;<strong>4F.4B&nbsp;<\/strong>contacts, front and back contacts metal to carbon, shall be suitable for working in series with the 110V AC, LED signal lamp rated at 15W confirming to&nbsp;<strong>RDSO spec. STS\/E\/Relays\/AC lit LED signal\/09-2002, BRA:941A, IRS:S 34 &amp; IRS:S 23&nbsp;<\/strong>(as applicable). The interlocking code for this unit shall be&nbsp;<strong>ABDHK.<\/strong><\/td><td><\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>Relay ON Aspect<\/td><td>Relay, plug-in type, Style&nbsp;<strong>\u2018ON\u2019<\/strong>&nbsp;aspect, AC lamp proving relay unit with in-built current transformer type, slow release neutral line relay<strong>, 4F.4B<\/strong>&nbsp;contacts, front and back contacts metal to carbon, shall be suitable for working in series with the primary winding of colour light signal&nbsp; transformer confirming to&nbsp;<strong>IRS:S 59 (110V AC\/12V AC) feeding 25\/33 Watt, double pole, double filament signal lamps&nbsp; confirming to BRS:941A, IRS:S 34 &amp; IRS:S 23<\/strong>&nbsp;(as applicable). The interlocking code for this unit shall be&nbsp;<strong>CFKMX.<\/strong><\/td><td>RDSO<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>Relay OFF Aspect<\/td><td>Relay, plug-in type, Style&nbsp;<strong>\u2018OFF\u2019<\/strong>&nbsp;aspect, AC lamp proving relay unit&nbsp; with in-built current transformer type, slow release neutral line relay,&nbsp;<strong>4F.4B<\/strong>&nbsp;contacts, front and back contacts metal to carbon , shall be suitable for working in series with the primary winding of colour light signal transformer confirming to&nbsp;<strong>IRS:S 59 (110V AC\/12V AC) feeding 25\/33 watt, double pole, double filament signal lamps confirming to&nbsp; BRS:941A, IRS:S 34 &amp; IRS:S 23<\/strong>&nbsp;(as applicable). The interlocking code for this unit shall be&nbsp;<strong>CFJKM.<\/strong><\/td><td>RDSO<\/td><\/tr><\/tbody><\/table><figcaption>Relay Route Aspect<br>Relay, plug-in type, Style \u2018<strong>ROUTE<\/strong>\u2019 aspect, AC lamp proving relay unit with in-built current transformer type, slow release neutral line relay,&nbsp;<strong>4F.4B<\/strong>&nbsp;contacts, front and back contacts metal to carbon, shall be suitable for working in series with the lighting circuit of junction type route indicator (5 Lamps, 110V\/25 watt, double pole, connected in parallel) confirming to&nbsp;<strong>BRS:942, IRS:S 34 &amp; IRS:S 23<\/strong>&nbsp;(as applicable). The interlocking code for this unit shall be&nbsp;<strong>CFKLX.<\/strong><br>RDSO<\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td>Relay Shunt Aspect<\/td><td>Relay, plug-in-type,&nbsp;<strong>Style \u2018SHUNT\u2019<\/strong>&nbsp;aspect, AC lamp proving relay unit with inbuilt current transformer type, slow release neutral line,&nbsp;<strong>2F.2B<\/strong>&nbsp;contacts, front and back contacts metal to carbon, shall be suitable for working in series with the lighting circuit of junction type route indicator (2 lamps, 110V\/25 Watt, double pole, connected in parallel) confirming&nbsp;<strong>to BRS:942, IRS:S 34 &amp; IRS:S 23<\/strong>&nbsp;(as applicable). The interlocking code for this unit shall be&nbsp;<strong>CFGJY<\/strong>.<\/td><td>RDSO<\/td><\/tr><\/tbody><\/table><figcaption>Relay QN1K, 6F\/6B<br>Relay,&nbsp;<strong>Non- AC immune<\/strong>, plug in type style&nbsp;<strong>QN1K,<\/strong>&nbsp;DC neutral line,&nbsp;<strong>24V, 1000 ohms 6F\/6B<\/strong>&nbsp;contacts front contacts metal to carbon and back contacts metal to metal\/carbon with plug board retaining clip &amp; connectors conforming to&nbsp;<strong>BRS:930, IRS:S 34 &amp; IRS:S 23 &amp; RDSO Spec. No. STS\/E\/Relays\/UEA(PI) dt.30.05.97&nbsp;<\/strong>(as applicable). The Interlocking code for this unit shall be&nbsp;<strong>BDEKX.<\/strong><br>RDSO<br>Relay QN1K, 4F\/4B<br>Relay,&nbsp;<strong>Non- AC immune<\/strong>, plug in type style&nbsp;<strong>QN1K,<\/strong>&nbsp;DC neutral line,&nbsp;<strong>24V, 1000 ohms 4F\/4B<\/strong>&nbsp;contacts front contacts metal to carbon and back contacts metal to metal\/carbon with plug board retaining clip &amp; connectors conforming to&nbsp;<strong>BRS:930, IRS:S 34 &amp; IRS:S 23 &amp; RDSO Spec. No. STS\/E\/Relays\/UEA(PI) dt.30.05.97&nbsp;<\/strong>(as applicable). The Interlocking code for this unit shall be&nbsp;<strong>BDEKX.<\/strong><br>RDSO<br>Relay QN1K, 8F\/8B<br>Relay,&nbsp;<strong>Non- AC immune<\/strong>, plug in type style&nbsp;<strong>QN1K,<\/strong>&nbsp;DC neutral line,&nbsp;<strong>24V, 1000 ohms 8F\/8B<\/strong>&nbsp;contacts front contacts metal to carbon and back contacts metal to metal\/carbon with plug board retaining clip &amp; connectors conforming to&nbsp;<strong>BRS:930, IRS:S 34 &amp; IRS:S 23 &amp; RDSO Spec. No. STS\/E\/Relays\/UEA(PI) dt.30.05.97&nbsp;<\/strong>(as applicable). The Interlocking code for this unit shall be&nbsp;<strong>ABCDF.<\/strong><br>RDSO<br>Relay QN1K, 12F\/4B<br>Relay,&nbsp;<strong>Non- AC immune<\/strong>, plug in type style&nbsp;<strong>QN1K,<\/strong>&nbsp;DC neutral line,&nbsp;<strong>24V, 1000 ohms 12F\/4B<\/strong>&nbsp;contacts front contacts metal to carbon and back contacts metal to metal\/carbon with plug board retaining clip &amp; connectors conforming to&nbsp;<strong>BRS:930, IRS:S 34 &amp; IRS:S 23 &amp; RDSO Spec. No. STS\/E\/Relays\/UEA(PI) dt.30.05.97&nbsp;<\/strong>(as applicable). The Interlocking code for this unit shall be&nbsp;<strong>ABCDE.<\/strong><br>RDSO<br>Relay QN1, 24V 8F\/8B<br>Relay,&nbsp;<strong>Non-AC Immune,&nbsp;<\/strong>plug-in-type,&nbsp;<strong>Style* \u2018QN1\u2019,<\/strong>&nbsp;DC Neutral line,&nbsp;<strong>24V, 8F.8B&nbsp;<\/strong>contacts, front and back contacts metal to carbon with plug board, retaining clip &amp; connectors confirming to&nbsp;<strong>BRS:930A, IRS:S 34 &amp; IRS:S 23&nbsp;<\/strong>(as applicable). The interlocking code for this unit shall be&nbsp;<strong>ABCDF.<\/strong><br>RDSO<br>Relay QN1, 24V, 12F\/4B<br>Relay,&nbsp;<strong>Non-AC Immune<\/strong>, plug in type , Style*&nbsp;<strong>\u2018QN1\u2019,<\/strong>&nbsp;DC neutral line ,&nbsp;<strong>24V, 12F\/4B<\/strong>&nbsp;contacts, front and back contacts metal to carbon with plug board, retaining clip &amp; connectors confirming to&nbsp;<strong>BRS:930A, IRS:S 34 &amp; IRS:S 23<\/strong>&nbsp;(as applicable). The interlocking code for this unit shall be&nbsp;<strong>ABCDE.<\/strong><br>RDSO<br>Relay QN1, 50V, 8F\/8B<br>Relay,&nbsp;<strong>Non-AC Immune,&nbsp;<\/strong>plug-in-type,&nbsp;<strong>Style* \u2018QN1\u2019,<\/strong>&nbsp;DC Neutral line,&nbsp;<strong>50V, 8F.8B&nbsp;<\/strong>contacts, front and back contacts metal to carbon with plug board, retaining clip &amp; connectors confirming to&nbsp;<strong>BRS:930A, IRS:S 34 &amp; IRS:S 23&nbsp;<\/strong>(as applicable). The interlocking code for this unit shall be&nbsp;<strong>ABDEF.<\/strong><br>RDSO<br>Relay QN1, 50V, 12F\/4B<br>Relay,&nbsp;<strong>Non-AC Immune<\/strong>, plug in type , Style*&nbsp;<strong>\u2018QN1\u2019,<\/strong>&nbsp;DC neutral line,&nbsp;<strong>50V, 12F\/4B<\/strong>&nbsp;contacts, front and back contacts metal to carbon with plug board, retaining clip &amp; connectors confirming to&nbsp;<strong>BRS:930A, IRS:S 34 &amp; IRS:S 23<\/strong>&nbsp;(as applicable). The interlocking code for this unit shall be&nbsp;<strong>ABCEF.<\/strong><br>RDSO<br>Relay QNA1, 8F\/8B<br>Relay,<strong>&nbsp;AC Immune,&nbsp;<\/strong>plug-in-type,&nbsp;<strong>Style* \u2018QNA1\u2019,&nbsp;<\/strong>DC Neutral line,<strong>&nbsp;24V, 8F.8B&nbsp;<\/strong>contacts, front and back contacts metal to carbon, with plug board, retaining clip &amp; connectors confirming to&nbsp;<strong>BRS:931A, IRS:S 60, IRS:S 34 &amp; IRS:S 23&nbsp;<\/strong>(as applicable). The interlocking code for this unit shall be&nbsp;<strong>ABDGH.<\/strong><br>RDSO<br>Relay QNA1, 12F\/4B<br>Relay,&nbsp;<strong>AC Immune<\/strong>, plug-in type, Style \u2018<strong>QNA1<\/strong>\u2019, DC neutral line,&nbsp;<strong>24V, 12F\/4B<\/strong>&nbsp;contacts front and back contacts metal to carbon, with plug board retaining clip &amp; connectors conforming to&nbsp;<strong>BRS:931A, IRS:S 60, IRS:S 34 &amp; IRS:S 23<\/strong>&nbsp;(as applicable). The interlocking code for this unit shall be&nbsp;<strong>ABDFH.<\/strong><br>RDSO<br>Relay QNA1K, 6F\/6B<br>Relay,&nbsp;<strong>AC Immune<\/strong>, plug-in-type, Style*&nbsp;<strong>\u2018QNA1K\u2019<\/strong>, DC Neutral line,&nbsp;<strong>24V, 1000 ohms<\/strong>&nbsp;<strong>6F.6B<\/strong>, contacts, front contacts metal to carbon and back contacts metal to metal\/carbon, complete with plug board, retaining clip &amp; connectors conforming to&nbsp;<strong>BRS:930A, IRS:S 60, IRS:S 34, IRS:S 23 &amp; RDSO Spec. No. STS\/E\/Relays\/UEA (PI) dt.30.05.97<\/strong>&nbsp;(Annexure-II) (as applicable). The interlocking code for this unit shall be&nbsp;<strong>CDEKY<\/strong>.<br>RDSO<br>Relay QT2,&nbsp; 9 ohm<br>Relay&nbsp;<strong>Non-AC immune<\/strong>&nbsp;plug in type style&nbsp;<strong>QT2<\/strong>&nbsp;DC neutral track&nbsp;<strong>9 ohm 2F.2B<\/strong>&nbsp;contacts front and back contacts metal to carbon complete with plug board retaining clip and connectors conforming to&nbsp;<strong>BRS:938A, IRS:S:34 &amp; IRS:S:23 &amp; firm\u2019s specification<\/strong>&nbsp;(as applicable). The interlocking code for this unit shall be&nbsp;<strong>DEFJX.<\/strong><br>RDSO<br>Relay QT2, 4 ohm<br>Relay,&nbsp;<strong>Non-AC Immune<\/strong>, plug-in type, Style&nbsp;<strong>\u2018QT2\u2019<\/strong>, DC Neutral track,&nbsp;<strong>4 ohms 2F.1B<\/strong>&nbsp;contacts, front and back contacts metal to carbon, complete with plug board, retaining clip and connectors confirming to<strong>&nbsp;BRS:938A, IRS:S 34 &amp; IRS:S 23 &amp; firm\u2019s specification<\/strong>&nbsp;(as applicable). The interlocking code for this unit shall be&nbsp;<strong>EHJKX<\/strong>.<br>RDSO<br>Relay QTA2, 9 ohm, 2F\/1B<br>Relay,&nbsp;<strong>AC Immune<\/strong>, plug-in-type, Style*&nbsp;<strong>\u2018QTA2\u2019<\/strong>, DC Neutral track,&nbsp;<strong>9 ohm 1.4V DC 2F. 1B<\/strong>&nbsp;contacts, front and back contacts metal to carbon, complete with plug board, retaining clip &amp; connectors confirming to&nbsp;<strong>BRS:939A, BRS:966 (Appendix F2), IRS:S 34 &amp; IRS:S 23<\/strong>&nbsp;(as applicable). The interlocking code for this unit shall be&nbsp;<strong>FGHKX.<\/strong><br>RDSO<br>Relay QTA2,&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp; &nbsp;9 ohm, 4F\/2B<br>Relay plug in type&nbsp;<strong>QTA2<\/strong>&nbsp;contacts&nbsp;<strong>4F.2B<\/strong>&nbsp;(1) Product code (2) Relay type \u2013&nbsp;<strong>QTA2<\/strong>&nbsp;(3) Nominal working voltage\/current \u2013&nbsp;<strong>1.4 DC<\/strong>&nbsp;(4) Contact configuration \u2013&nbsp;<strong>4F\/2B<\/strong>&nbsp;(5) Coil Resistance in ohms \u2013&nbsp;<strong>9<\/strong>&nbsp;(6) Maximum full operate current \u2013&nbsp;<strong>1.25 timed of pick up current (Max.)<\/strong>&nbsp;(9) Interlocking&nbsp; &#8211;&nbsp;<strong>FGHKX<\/strong>&nbsp;(10) AC Immunity \u2013&nbsp;<strong>At 120V AC 50 Hz&nbsp;<\/strong>(11) Reverse Polarity Test \u2013&nbsp;<strong>N.A.<\/strong>&nbsp;(12) Interruption Test \u2013&nbsp;<strong>N.A.<\/strong>&nbsp;(13) Specification No.&nbsp;<strong>BRS:939A &amp; BRS:966 (Appendix \u2013 F2), IRS:S 34, IRS:S 23<\/strong>&nbsp;(14) Remarks: AC Immune neutral Track Relay.&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;<br>RDSO<br>Relay QS3, 4F\/4B<br>Relay,&nbsp;<strong>Non-AC Immune<\/strong>, plug-in type, Style \u2018<strong>QS3<\/strong>\u2019, DC neutral line,<strong>12V,1000 ohms 4F.4B<\/strong>&nbsp;contacts, front contacts metal to&nbsp; carbon and back contacts metal to metal\/carbon, complete with plug board, retaining clip &amp; connectors confirming to&nbsp;<strong>BRS:930, IRS:S 34 &amp; &nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;&nbsp;IRS:S 23 and firm\u2019s specification<\/strong>&nbsp;(as applicable). The interlocking code for this unit shall be&nbsp;<strong>CDEKX.<\/strong><br>RDSO<br>Relay QSPA1, 8F\/4B<br>Relay,&nbsp;<strong>AC Immune,<\/strong>&nbsp;plug-in-type, Style*&nbsp;<strong>\u2018QSPA1\u2019<\/strong>, DC Neutral line, slow to pickup,&nbsp;<strong>24V, 8F. 4B<\/strong>&nbsp;contacts, front &amp; back contacts metal to carbon, complete with plug board, retaining clip &amp; connectors confirming to&nbsp;<strong>BRS:933A, IRS:S 60, IRS:S 34 &amp; IRS:S 23<\/strong>&nbsp;(as applicable). The interlocking code for this unit shall be&nbsp;<strong>ABDEJ.<\/strong><br>RDSO<\/figcaption><\/figure>\n\n\n\n<p><strong>ROLEX METAL DISTRIBUTORS<br>57-A Khatargalli<br>Thakurdwar<br>Mumbai &#8211; 400 002 India<br>0091-22-23858802<br>0091-22-23823963<br>marketing@rolexmetals.com<br>www.rolexmetals.com<\/strong><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Product Code Description Approved By Relay AC LED. Relay, plug-in-type,&nbsp;Style* \u2018AC LED\u2019&nbsp;all aspects, AC Lamp proving relay unit with in-built current transformer type, slow release neutral line relay,&nbsp;4F.4B&nbsp;contacts, front and back contacts metal to carbon, shall be suitable for working in series with the 110V AC, LED signal lamp rated at 15W confirming to&nbsp;RDSO spec. [&hellip;]<\/p>\n","protected":false},"author":1,"featured_media":0,"parent":0,"menu_order":0,"comment_status":"closed","ping_status":"open","template":"","meta":{"footnotes":""},"class_list":["post-2","page","type-page","status-publish","hentry"],"_links":{"self":[{"href":"https:\/\/rolexiron.com\/index.php\/wp-json\/wp\/v2\/pages\/2","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/rolexiron.com\/index.php\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/rolexiron.com\/index.php\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/rolexiron.com\/index.php\/wp-json\/wp\/v2\/users\/1"}],"replies":[{"embeddable":true,"href":"https:\/\/rolexiron.com\/index.php\/wp-json\/wp\/v2\/comments?post=2"}],"version-history":[{"count":2,"href":"https:\/\/rolexiron.com\/index.php\/wp-json\/wp\/v2\/pages\/2\/revisions"}],"predecessor-version":[{"id":629,"href":"https:\/\/rolexiron.com\/index.php\/wp-json\/wp\/v2\/pages\/2\/revisions\/629"}],"wp:attachment":[{"href":"https:\/\/rolexiron.com\/index.php\/wp-json\/wp\/v2\/media?parent=2"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}